UV Ultraviolet Fluorescence Sulfur In Oil Tester

  • UV Ultraviolet Fluorescence Sulfur In Oil Tester
  • UV Ultraviolet Fluorescence Sulfur In Oil Tester
  • UV Ultraviolet Fluorescence Sulfur In Oil Tester
  • UV Ultraviolet Fluorescence Sulfur In Oil Tester
UV Ultraviolet Fluorescence Sulfur In Oil Tester
  • DOOWAY
  • CHINA
  • 30 days
  • 30 sets per month

Sulfur content in liquid,Configurating laptop, preinstalled software in Chinese & English interface, easy to operate;
Determination of trace sulfur in liquid samples.The high voltage of PMT can be adjusted at will, and the calibration of the standard sample curve can adopt single point or multi-point calibration, which is easy to operate;
Ultraviolet fluorescence analysis technique has high sensitivity, linearity and anti-interference ability, and the results are accurate and reliable;
Instrument Packing:host, autosampler, laptop, printers, etc.

Sulfur content in liquid


UV Ultraviolet Fluorescence Sulfur In Oil Tester Overview

Sulfur content in liquid DP500T meets the requirements of ASTM D5453, D6667, D7183, GB/T 34100-2017, GB/T35582, GB/T11060.8, SH/T 0689, ISO 17198 and DB51/T 1689 standards. IUltraviolet fluorescence analysis technique  is used to detect the content of trace sulfur in liquid samples. Determination of trace sulfur in liquid samples  is used in petroleum, petrochemical, chemical and environmental protection fields. Sulfur content in liquid can be used to determine the total sulfur content in gasoline, diesel, crude oil, distillate oil, hydrocarbon and engine fuel, petroleum gas, petrochemical products and coal, Meet the analysis requirements of sulfur content in gasoline (National V) and diesel (National IV).


Determination of trace sulfur in liquid samples


Sulfur content in liquid Technical Specifications

Measuring range:0.1mg/L~20000mg/L;

Lower limit of detection:0.1mg/L;

Sample tray:156, Solvent bottle: 2; Waste liquid bottle: 4;

Primary liquid injection volume: 0.1μl~250μl;

Repeatability:

0.1mg/L≤X<1.0mg/L,Absolute error ≤±0.2mg/L;

1.0mg/L≤X<100mg/L,Relative error ≤8%;

100mg/L≤X≤10000mg/L,Relative error ≤5%。

Gas requirements:Argon ≥ 99.99%;Oxygen ≥99.99%;

Temperature range:Room temperature ~1100°C,Accuracy:≤±2°C;

Power:1.8KW,Weight:46Kg;

Power supply:220VAC±10%,50±0.5Hz;

Ambient temperature:5~30°C;Humidity:35°C, 20~90%RH (no condensation).


Ultraviolet fluorescence analysis technique